BT-11x Membrane Conductivity Hardware:
Use the BekkTech Conductivity Cell or Clamp to obtain in-plane ionic conductivity data on your bare membrane sample.

BT-110 Conductivity Clamp:
The BT-110 Conductivity Clamp is used to obtain in-plane resistance and ionic conductivity of bare ionomer membrane samples. The Conductivity Clamp is designed to be used in a humidity chamber or in a beaker.
The advantage of the 4-electrode measurement is the ability to measure resistance due only to charge transport while excluding interfacial and charge transfer resistances. By measuring only the resistance due to ion transport, accurate assessment of in-plane membrane conductivity can be made.

Valuable time and money can be saved by analyzing ion charge transport resistance prior to catalyzation of the membrane and assembly of the MEA into a fuel cell.

BT-112 Conductivity Cell:
Assemble your bare membrane sample into the Conductivity Cell. The Conductivity Cell is then assembled into your Scribner Associates or Fuel Cell Technologies, Inc. fuel cell hardware.
BT-112 in SAI FC

Connect the fuel cell hardware to your test stand to control the temperature, humidity, gas type, and pressure of the membrane sample under test.

The advantage of the 4-electrode in-plane conductivity measurement is the ability to measure impedance (resistance) due only to charge transport and exclude interfacial and charge transfer resistances. By considering only resistance due to ion transport, accurate assessment of in-plane membrane conductivity can be made.

BT-115 Conductivity Cell:
Assemble your bare membrane sample into the Conductivity Cell. The Conductivity Cell is then assembled into your ElectroChem, Inc. fuel cell hardware. Connect the fuel cell hardware to your test stand to control the temperature, humidity, gas type, and pressure of the membrane sample under test.
The advantage of the 4-electrode in-plane conductivity measurement is the ability to measure impedance (resistance) due only to charge transport and exclude interfacial and charge transfer resistances. By considering only resistance due to ion transport, accurate assessment of in-plane membrane conductivity can be made.


Description

BT-110 Conductivity Clamp:

Tests pure membrane samples – fabrication of a catalyzed sample (CCM or MEA) is not required
In-plane, 4-electrode technique
Recommended membrane sample size: 25mm x 10mm
Designed for use in an environmental chamber or non-conductive liquid
Temperatures up to 150 °C, High temperature option to 250 ºC

BT-112 & BT-115 Conductivity Cell:

Designed to be used with your existing test stand hardware
Compatible cell fixtures: BT-112 (Scribner & Fuel Cell Technologies); BT-115 (Electrochem, Inc.)
High temperature option to 250 ºC

Features of the BekkTech In-Plane Conductivity Cell:

Tests pure membrane samples. Fabrication of a catalyzed sample (CMM or MEA) is not required.
In-plane, four electrode technique
Control of humidity and pressure using your existing fuel cell test system
High temperature testing (to 120 °C)
Membrane Conductivity Clamp is removable allowing you to use the clamp for tests in a beaker or a humidity chamber